Private Mold: | NO | Products Status: | Stock, Used, Stock |
---|---|---|---|
Ports: | ≥ 48 | Transmission Rate: | 10/100/1000Mbps |
Function: | LACP, SNMP | Communication Mode: | Full-Duplex & Half-Duplex |
Switch Capacity: | 56 Gb/s | Product Name: | H3C S5720-56c-Pwr-Hi-AC1 Switch |
Type: | Rack |
Item
|
H3C S5720-56c-Pwr-Hi-AC1 Switch
|
Brand Name
|
H3C
|
Item |
Description |
---|---|
Memory (RAM) | 4 GB |
Flash | 512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) | 39.31 years when no interface card is configured; 37.53 years when a 4-port 10GE interface card is configured |
Mean time to repair (MTTR) | 2 hours |
Availability | > 0.99999 |
Service port surge protection | Common mode: ±1 kV |
Power supply surge protection | ±6 kV in differential mode, ±6 kV in common mode |
Dimensions (H x W x D) |
|
Weight (with packaging) | 10.6 kg (23.37 lb) |
Stack ports | Four fixed 10GE SFP+ ports on the front panel or ports on the 4-port 10GE SFP+ rear interface card |
RTC | Supported |
RPS | Not supported |
PoE | Supported |
Rated voltage range | 100 V AC to 240 V AC, 50/60 Hz |
Maximum voltage range | 90 V AC to 264 V AC, 47 Hz to 63 Hz |
Maximum power consumption (100% throughput, 100% PoE loads, full speed of fans) |
Not providing the PoE function: 188.74 W 100% PoE loads: 1036 W (system power consumption: 296 W, PoE: 740 W) |
Typical power consumption (30% of traffic load)
|
137.8 W |
Operating temperature |
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Short-term operating temperature |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature | -40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) | < 64.6 dB(A) |
Relative humidity | 5% to 95%, noncondensing |
Operating altitude | 0-5000 m (0-16404 ft.) |
Certification |
|
Part number | 02350MTQ |